Troubleshooting & FAQ
On this page
Common Problems
"TIA Portal not found"
Cause: TIA Portal is not installed or wrong version.
Solution:
- Check if TIA Portal V15 through V21 is installed
- Make sure the Openness components are installed
- Restart AnyAutomation Studio and try connecting again
"Access denied" when opening
Cause: Insufficient permissions to access TIA Portal or the project file.
Solution:
- Run AnyAutomation Studio as Administrator
- Ensure the project file is not read-only
- Check that no other instance has the project open exclusively
The project is no longer available during an operation
Cause: The open project was closed or reloaded in TIA Portal while Studio was working with it.
Solution:
- Close the project
- Open it again
- For large projects: Use Attach Mode
Export takes very long
Cause: Many blocks or slow hard drive.
Solution:
- Export in smaller batches
- Use an SSD
- Close other applications
- Watch progress in the Status Bar and the Output panel
"TIA Portal session not available"
Cause: The connection to TIA Portal could not be established or was blocked.
Solution:
- Ensure the AnyAutomation Studio installation is complete
- Check that antivirus software is not blocking AnyAutomation Studio
- Restart AnyAutomation Studio
- See the Output panel for connection details
Download or update does not start
Cause: The company network only allows listed addresses and blocks the download address.
Solution:
- Have
anyautomation.chanddownloads.anyautomation.challowed in the firewall or proxy, plusaccount.anyautomation.chfor the sign-in before a download on the website - Then check for updates again with Check Now under Settings → General → Startup
- Alternatively, download the installer from anyautomation.ch/download and install it manually; before the download, you sign in with your free account (email address and code)
Sign-in for the download is refused
Cause: The download needs a free account with a permanent email address, for example your work address.
Solution:
- Sign in with a permanent email address, for example your work address
- If the code does not arrive, check the spam folder of your mailbox
License window: the date and time are not correct
Cause: The date and time of your computer are far behind. Studio then cannot check your license and stops the licensed features until the clock is right.
Solution:
- Open Settings in Windows, then Time & language > Date & time
- Turn on Set time automatically and click Sync now
- Restart Studio; your license applies again without a new activation
License window: "Studio could not identify this computer"
Cause: Your license is bound to the computer it was activated on. The license window shows "Studio could not identify this computer, so your license cannot be checked right now", and the licensed features are unavailable for now. Your license and its activation are kept.
Solution:
- Restart Studio; you do not need to activate your license again
- If the message appears again, restart Windows and then start Studio
- If it still appears after restarting Windows, contact support
Update cannot be installed on this computer
Cause: On some company PCs, security software or company policies prevent AnyAutomation Studio from installing an update. Studio then does not install the update and shows a message with the download link.
Solution:
- Check for updates again with Check Now under Settings → General → Startup; a short block by security software often clears by itself
- If the message stays, contact your IT department and ask them to allow updates of AnyAutomation Studio on this PC
- Alternatively, download the installer from anyautomation.ch/download and install it manually; before the download, you sign in with your free account (email address and code)
Windows asks for an administrator when updating, or the update was not installed
Cause: AnyAutomation Studio is installed for all users of the computer, so Windows asks for administrator approval before an update is installed. If the approval is declined, not given in time or not possible on this computer, Studio keeps running with the current version and the update stays ready.
Solution:
- Click Restart to Update in the gear menu, or Try Again in the notification, and approve the Windows prompt; if Windows asks for a user name and password, an administrator enters them
- If you cannot approve installations on this computer, ask your IT department to install the update
- Alternatively, download the installer from anyautomation.ch/download and have it installed by someone with administrator rights; before the download, you sign in with your free account (email address and code)
FAQ
Q: Can I work in TIA Portal during export? A: No. During bulk operations, TIA Portal shows a dialog that blocks user interaction until the operation completes. This prevents conflicts and ensures data integrity.
Q: Are comments preserved during export/import? A: Yes, all block attributes are stored in the XML file.
Q: Does the application support Safety projects? A: Yes, F-blocks are fully supported. Some operations require Safety login.
Q: Can I open multiple projects at once? A: Yes, with no limit on the number of open projects, including multiple projects of the same TIA Portal major version, each with its own isolated TIA Portal session. You switch between open projects by clicking the project name at the top of the Project Explorer or the TIA entry in the status bar; the Project Explorer always shows the active project. Restricted only by the rule that the same project file or the same already-attached TIA Portal instance cannot be added twice.