Skip to content

EPLAN to TIA Hardware Import

On this page

The EPLAN to TIA hardware import is included in the Pro+ and Enterprise plans. It reads the PLC hardware defined in an open EPLAN project, compares it against the hardware already present in your TIA Portal project, and lets you bring the EPLAN hardware into TIA without re-modelling it by hand.

Prerequisites

  • An open EPLAN project that contains PLC hardware (stations, racks and modules).
  • An open and connected TIA Portal project to import the hardware into.
  • A Pro+ or Enterprise license. The import is part of the tier; on a lower tier, starting the import shows an upgrade dialog instead of opening the comparison view.

Starting the Import

Open both projects first: your EPLAN project (see EPLAN Integration) and the TIA Portal project you want to import into. Then run Import Hardware from EPLAN…. You can start it two ways:

  • From the Command Palette, search for Import Hardware from EPLAN….
  • From the circuit-board icon in the title bar of the EPLAN Project Explorer.
  • From the chat: ask the EPLAN Engineer agent to import the hardware into TIA; after your confirmation it opens the same comparison view.

A comparison view titled EPLAN to TIA Hardware opens.

The Comparison View

The view lists the EPLAN project's PLC hardware as a tree. The hardware is grouped from stations down to their racks and modules, so you can expand a station to see what it contains.

Each row has these columns:

  • Name: the name of the station, rack or module.
  • Type: the device type.
  • Article: the article number.
  • Firmware: the firmware version.
  • Address: the configured address.
  • Status: a badge that tells you how this piece of hardware compares against your TIA project.

The Status badge shows one of:

  • New: the hardware exists in EPLAN but is not yet in the TIA project.
  • Changed: the hardware exists in both, but some detail differs between EPLAN and TIA.
  • Unchanged: the hardware matches what is already in the TIA project.
  • Only in TIA: the hardware exists in the TIA project but is not in the EPLAN project. A rack or module that only TIA has appears inside its station; a whole station that only TIA has is listed after the EPLAN stations, with the name TIA Portal shows for it.
  • Not exchanged: the device is in the TIA project, but TIA Portal does not pass it on to EPLAN, for example an HMI panel. It is listed at the end so you see it, and it is not compared.

Stations are compared by their device name, modules by their name, or by their slot and article number when EPLAN names them differently. Studio compares the article number, firmware, address range and IP address wherever both sides carry a value. Firmware versions and address ranges that EPLAN and TIA Portal write differently, for example V2.9 and V2.9.0, count as the same, so matching hardware shows Unchanged. The columns still show the values as each side writes them. For a module the address range is its input and output addresses, so a module that EPLAN places on other addresses than TIA Portal shows Changed.

Point at a Changed badge to see what differs and which value TIA Portal has. The counters below the tree show how many stations and modules have each status.

Filtering and Refreshing

  • An EPLAN project can keep its PLC hardware in several PLC configuration sets. Use the Configuration set dropdown to compare only one set, or keep All configuration sets to compare every set. When you compare one set, TIA Portal stations that belong to another set are not listed as Only in TIA. Each entry shows how many PLCs the set contains. Studio remembers the set you chose last for each EPLAN project and selects it again the next time you open the comparison; if that set no longer exists, All configuration sets is selected.
  • Use the station filter dropdown above the tree to narrow the view to a single station. Pick a station to focus on it, or clear the filter to see all of them.
  • Click Refresh to read the EPLAN and TIA projects again and rebuild the comparison after you have changed either side.

Comparing with a Project Opened Offline

You can also compare without TIA Portal running. Open the TIA project offline in the Project Explorer with Open TIA Project (Offline), then run Import Hardware from EPLAN…. The view says that it compares with the TIA project opened offline and shows the same statuses, articles, firmware and addresses.

The comparison is read only: Import Hardware, Push to EPLAN and Push Selected to EPLAN are greyed out. To import or push, close the offline project and connect to TIA Portal.

A few things look different from a comparison with TIA Portal running:

  • Devices that TIA Portal does not pass on to EPLAN, such as HMI panels, show as Only in TIA instead of Not exchanged.
  • Modules of GSD devices without an article number are not listed.
  • Drive components can show other article numbers, because the project file keeps the article numbers TIA Portal stores for them.
  • The comparison sees what was last saved in TIA Portal. Save the project in TIA Portal first if you changed it there.

Importing the Hardware

When the comparison looks right, click Import Hardware. The EPLAN hardware of the chosen configuration set, or of every set, is brought into the connected TIA project. When it finishes, Studio compares again and a message tells you how many of the stations arrived in TIA Portal, for example "3 of 3 stations imported", and names the stations that did not arrive. Studio prepares the EPLAN hardware for TIA Portal before the import, so that the CPU keeps the network interface, the IP address and the PROFINET name that EPLAN plans for it. If TIA Portal could not take over everything, for example a module that is not installed in your TIA Portal, the message says that TIA Portal reported problems; click Show Details to read the messages of TIA Portal. If none of the stations arrived, or TIA Portal stopped the import because of errors, the message is an error.

If stations of the EPLAN hardware already exist in the TIA project under exactly the same name, Studio asks before it imports. The question names these stations and says that the import deletes them in TIA Portal and builds them again from EPLAN, so everything you set up on them only in TIA Portal is lost, such as the PLC program, module parameters, module names and network settings. Click Replace and Import to continue, or Cancel to stop without changing anything. When no station is replaced, the import starts right away. Stations you replace this way count in the import result like new stations, and they get the network data that EPLAN plans for them, such as the IP address and the PROFINET name.

If the EPLAN project was changed in Studio after the comparison, for example by an edit or the AI chat, Import Hardware does not import. Studio shows a warning with a Refresh button: refresh the comparison, check it and import again. Changes you make directly in EPLAN are not noticed, so click Refresh yourself after working in EPLAN.

You can re-run the comparison afterwards with Refresh to see the imported stations reflected in the status badges.

Network data of the imported stations

Right after the import, Studio takes over the network data that EPLAN plans for the stations this import created in TIA Portal: the IP address, the subnet mask, the PROFINET name, the subnet and the IO system. You do not need to click Write Network Data to TIA Portal for these stations. Stations that were already in TIA Portal before the import keep their network data; to bring them in line with EPLAN, use Write Network Data to TIA Portal (see below).

An IO system is created only on a device that works as IO controller in TIA Portal, and the IO devices that EPLAN assigns to it are connected to it. When EPLAN plans the IO system on a device without IO controller function, for example on a bus coupler, Studio creates no IO system, assigns no station to it and tells you so. A station that TIA Portal already connects to another IO system is never moved.

A second message then names for how many of the imported stations the network data was taken over completely. When something could not be taken over, click Show Details: one line per station and interface names what was set and what was not, with the reason, for example a station that TIA Portal could not create or a value that TIA Portal refused.

Network Data

When the EPLAN hardware carries network data, the comparison shows three more columns:

  • IP Address: the IP address of each network interface of the station, with the subnet mask.
  • Subnet: the subnet the interface is connected to.
  • PROFINET Name: the PROFINET device name.

A station whose IP address, subnet mask, PROFINET name or subnet differs from TIA Portal shows Changed. Point at the badge to see each differing value, together with the interface it belongs to.

With EPLAN 2026, Studio reads the hardware in the newest AutomationML format that your TIA Portal version can import, and the line above the comparison names the format, for example Source: EPLAN hardware, AutomationML AR APC V1.4.0. EPLAN 2025 passes on IP addresses and subnet masks, but no PROFINET names and no subnets, so these cells stay empty there.

Writing the network data to TIA Portal

  1. Click Write Network Data to TIA Portal. The button is available when at least one station has network data that differs from TIA Portal.
  2. A confirmation lists every change, for example PLC_1, X1, IP address: 192.168.0.11 becomes 192.168.0.10. Click Write to TIA Portal to continue.
  3. TIA Portal takes over the IP addresses, subnet masks and PROFINET names and connects the interfaces to the subnet planned in EPLAN; a subnet that does not exist yet is created. When an IP address or PROFINET name was changed in TIA Portal after the comparison, that station is left as it is and reported.
  4. A message names how many stations took over the network data and which changes failed, and the comparison is refreshed.

Type Check

The Type Check column compares the part that EPLAN assigns to the PLC box of each module with the article of the module in TIA Portal:

  • Match: the order number or type of the EPLAN part fits the TIA article.
  • Mismatch: EPLAN and TIA Portal name different articles. Point at the badge to see both.
  • No part: the PLC box in EPLAN has no part assigned.
  • Unknown: no PLC box in EPLAN belongs to this module.

The counter Type mismatches below the tree shows how many modules differ. To correct a part in EPLAN, use the Articles section of Function Properties (see EPLAN Integration).

Importing Selected Modules

Instead of importing the whole EPLAN hardware, you can create single stations and modules in TIA Portal:

  1. In the Import column, tick the new stations and modules you want. Only rows with the status New can be ticked. A new station is created together with its head module, for example its CPU.
  2. Click Import Selected Modules.
  3. Studio looks every article up in the hardware catalogue of TIA Portal and uses the version that matches the firmware in EPLAN. When the catalogue does not have that firmware, Studio takes the newest version and says so. A confirmation lists what TIA Portal creates and what is skipped, with the reason, for example a GSD device, a module without an article number or a slot that is already occupied in TIA Portal. Click Import to continue.
  4. A message names how many stations and modules were created, skipped and failed, and the comparison is refreshed.
  5. For the new stations, Studio then takes over the network data from EPLAN, the same way as after Import Hardware (see Network data of the imported stations), and shows a second message with the result.

Writing network data and importing selected modules need TIA Portal attached; with a project opened offline both buttons are greyed out.

PLC Card Pages from TIA Portal

When the hardware is planned in TIA Portal, Studio creates the EPLAN pages of the PLC cards for you. Select the stations in the comparison (or show all of them) and choose PLC Card Pages from TIA Portal:

  1. When modules of these stations are only in TIA Portal, Studio offers Push to EPLAN first; choose Continue Without to create pages only for the cards that are already in EPLAN.
  2. Studio gives every card a new page in the structure of the page the card sits on, or, for a card that is not on a page yet, in the structure of another card of the same station, counted on from the last page there. A page name EPLAN already set is kept, and no existing page is overwritten.
  3. A confirmation lists the pages; Create Pages lets EPLAN generate them, and Open Page shows the first new page.

Needs the EPLAN schematic generator and PLC and bus extension options. A change made this way by the assistant can be undone with Discard AI Changes.

Readdress from TIA

Readdress from TIA gives every EPLAN PLC card that matches a TIA Portal module the start addresses of that module. A confirmation lists each card with its old and new address range and the cards that are skipped with the reason, for example a card without a matching TIA module. Studio readdresses the cards one after the other and compares again; the notification says how many cards still differ. Needs the EPLAN PLC and bus extension option and works with TIA Portal attached or with a project opened offline.

Pushing TIA Portal Hardware Back to EPLAN

When addresses, device names or network settings were finalised in TIA Portal, you can write them back into the schematic instead of entering them in EPLAN again. The round trip works in the same comparison view. You can push the hardware of the whole TIA Portal project, as described here, or only the devices you choose (see Pushing Selected Devices to EPLAN).

  1. Click Push to EPLAN in the title bar of the comparison view.
  2. A dialog explains what happens. Choose how EPLAN finds its devices in the TIA Portal hardware: Match by Object ID for hardware that came from EPLAN, or Match by Name for hardware that was created in TIA Portal. Click Cancel to stop.
  3. Studio reads the hardware of the open TIA Portal project and runs the EPLAN project check first. When the check reports open errors, nothing is written; the messages are shown in the Check Results view and the Problems panel (see EPLAN Project Check). Fix them in EPLAN and push again.
  4. EPLAN takes the hardware over. A message tells you how many PLC devices and connection points were changed, added and removed, and how many new messages EPLAN reported. These messages appear in the Problems panel.
  5. Click Refresh to compare again. The pushed stations, drives and GSD devices now show Unchanged. Devices that TIA Portal does not pass on to EPLAN, such as HMI panels, show Not exchanged.

Things to know:

  • TIA Portal is only read. Nothing in your TIA Portal project changes.
  • Devices of the EPLAN project that the TIA Portal hardware does not contain stay as they are and are not marked for deletion.
  • Within the pushed devices, EPLAN marks the objects that TIA Portal no longer has for deletion, for example a module you removed in TIA Portal. These objects stay in EPLAN and are only marked. Review them in EPLAN before you delete them.
  • Push to EPLAN pushes the hardware of the whole TIA Portal project. When TIA Portal can export the hardware only device by device, the push stops before anything is written in EPLAN. Select the devices in the comparison and use Push Selected to EPLAN instead, or check the export messages in TIA Portal and push again.
  • TIA Portal can leave single devices out of its export, for example HMI panels whose device type it cannot write. Studio then names these devices and asks before it pushes the rest: click Push Anyway to continue or Cancel to stop. The skipped devices stay as they are in the EPLAN project; the final message names them again. Any other export error stops the push and shows the messages of TIA Portal.
  • The push needs the PLC and Bus Data Import and AutomationML modules of your EPLAN licence. Without them, Push to EPLAN and Push Selected to EPLAN are greyed out and their tooltip names the missing module.

Pushing Selected Devices to EPLAN

When only some devices changed in TIA Portal, you can push just these devices and leave the rest of the EPLAN project alone.

  1. In the comparison view, tick the checkbox in front of each PLC, drive or GSD device you want to push. The checkbox in the column header selects every device that can be pushed. HMI devices and devices that exist only in EPLAN cannot be selected; point at their checkbox to see why.
  2. Click Push Selected to EPLAN. The button is available as soon as at least one device is ticked.
  3. A confirmation lists the chosen devices. Choose how EPLAN finds them in the TIA Portal hardware:

    • Match by Name (preselected): the usual choice for devices that were created in TIA Portal.
    • Match by Object ID: for TIA Portal hardware that was created from this EPLAN project.

    Click Cancel to stop.

  4. Studio reads only the chosen devices from TIA Portal and runs the EPLAN project check first, as for the whole push. When the check reports open errors, nothing is written. If TIA Portal cannot export one of the chosen devices, Studio names it and asks whether to push the other devices: click Push Anyway to continue or Cancel to stop. The device that was not exported stays as it is in EPLAN.
  5. EPLAN takes the devices over. A message tells you how many PLC objects were changed, added and removed and how many new messages EPLAN reported. It also names, per device, the objects EPLAN marked for deletion because TIA Portal no longer has them, for example a module you removed in TIA Portal. These objects stay in EPLAN and are only marked.

You can also run Push Selected Devices to EPLAN… from the Command Palette. It shows a list of the devices that can be pushed; pick the ones you want and continue with the confirmation as above.

Protection of the Other Devices

Both Push to EPLAN and Push Selected to EPLAN protect the devices you do not push:

  • The other devices of the EPLAN project stay as they are and are not marked for deletion. When EPLAN marks objects outside the pushed devices for deletion during the push, Studio removes these marks again. The result message tells you how many deletion marks Studio put back.
  • If the push would change anything outside the chosen devices, Studio undoes the whole push. A message tells you that the EPLAN project is unchanged.
  • In the rare case that Studio reports that EPLAN could not undo a push, check the PLC devices and their deletion marks in the EPLAN project before you continue.

Creating PLC Hardware in EPLAN from TIA Portal

When TIA Portal has stations or modules that EPLAN does not have yet, Create in EPLAN… in the hardware comparison creates them as new PLC devices in EPLAN. It needs the EPLAN PLC and bus extension option, and the EPLAN option for the parts management API to find the parts.

  1. Optionally tick the new modules you want in the import column; without a selection Studio takes every station and module of the shown stations that only TIA Portal has.
  2. Choose Create in EPLAN…. Studio looks every module up in the EPLAN parts database by its order number and lists the part each module gets, or why it will be skipped (no part found, or several parts match).
  3. Confirm with Continue, then choose Create Unplaced or Place on Page… (page, then the position of the first device; the next devices follow at a distance of 40 mm).

EPLAN creates the devices in one step with the station, rack, slot, firmware and start address of each module, and the IP address, PROFINET name and subnet mask where the module has one network port. Modules that EPLAN already has are skipped; to update them, use Push to EPLAN. A module whose part has no PLC box in EPLAN is skipped as well. Show Skipped in the message lists the skipped modules with the reason, and the comparison is reloaded. The new stations then appear on the EPLAN side of the comparison. TIA Portal is only read.

Looking Up a Module in the EPLAN Parts

Look Up in EPLAN Parts in the hardware comparison opens the EPLAN Parts editor with the order number of a TIA Portal module, so you can see its part, GSD file and PLC type designation (see EPLAN Symbols, Parts and Master Data).

Showing a Module in Your Running EPLAN

While Studio is connected to the EPLAN you have open, every station and module with an EPLAN device tag shows a Show in EPLAN button in the comparison. It opens the page of the device in your EPLAN and selects it. See Working with Your Running EPLAN.

Pushing with the AI Assistant

You can also ask the EPLAN Engineer agent in the chat to push the TIA Portal hardware to EPLAN, either the whole hardware or only the devices you name. It asks for your confirmation first.

A push by the assistant can be undone with Discard AI Changes (see EPLAN Integration). This undoes the push together with the changes the assistant made after it while answering the same message. Changes the assistant made in EPLAN before the push, while answering that message, are kept.

Network Data and Modules with the AI Assistant

You can ask the EPLAN Engineer agent to write the network data into TIA Portal, to import selected new stations and modules or to report the type check. It reads the comparison first, asks for your confirmation before anything is written to TIA Portal and reads the comparison again afterwards. When it imports new stations, it also takes over their network data from EPLAN and tells you what could not be taken over.

PLC Card Pages and Addresses with the AI Assistant

You can ask the EPLAN Engineer agent to create the PLC card pages of TIA Portal stations or to readdress the EPLAN cards from TIA Portal. It asks for your confirmation first and lists the modules that are missing in EPLAN.

PLC Hardware with the AI Assistant

Ask the EPLAN Engineer agent to "create the PLC of my TIA project in EPLAN": it reads the TIA Portal hardware, creates what EPLAN does not have after your confirmation and tells you which modules it skipped and why. It can also look up the part of a TIA Portal card by its order number.

Availability

The EPLAN to TIA hardware import comes with the Pro+ and Enterprise plans, the same access level as the other EPLAN features. There is no separate purchase. After upgrading to Pro+ or Enterprise, sign out and sign back in (or run Licensing: Refresh License from the Command Palette) so the new plan takes effect.